← All IP · the catalog
Motor, Power & Sensor Control

Push-Pull DC-DC Converter Controller

APB4 push-pull DC-DC gate-timing controller with OC/OV/trip supervision and a structural safe-state — ASIL-D SEooC.

Request this IP →Browse the catalog
ASIL-D
target
100.00%
SPFM
100.00%
LFM
PASS
FMEDA
2.3K
gates
1.0.0
version
Interfaces at a glance

Block diagram

dcdc_pp19 portsapb_slave8 signalsgate_agate_bocovclkrst_ninterruptdcdc_irqsafety / statustrip_n · err_clear · err_valid
Place-and-route snapshot

Physical implementation

Push-Pull DC-DC Converter Controller routed place-and-route layout on the Nangate45 PDK
A real synthesis and place-and-route pass on this RTL, routed on the open Nangate45 / FreePDK45 PDK — evidence the block closes physically, not just in simulation. Target-PDK timing, area, and power sign-off figures are shared under NDA.
The deliverable

What you’re licensing

APB4 push-pull DC-DC gate-timing controller with OC/OV/trip supervision and a structural safe-state — ASIL-D SEooC. It is delivered as a licensable soft-IP block engineered as an ASIL-D Safety Element out of Context — not just RTL, but the complete functional-safety work package needed to carry it into an ISO 26262 program:

Synthesizable RTL
Portable, vendor-neutral SystemVerilog that drops onto your existing SoC fabric — no foundry or EDA-tool lock-in.
Per-IP FMEDA report
SPFM / LFM / PMHF computed against the ASIL target per ISO 26262-5 — the quantitative analysis your assessor asks for.
Safety manual
Assumptions of use, the safety mechanisms and their diagnostic coverage — written to drop straight into your safety case.
IP-XACT + integration docs
A machine-readable descriptor plus register and integration documentation for fast, low-risk bring-up.
Self-checking testbench
A self-checking testbench and a one-command build, so you can reproduce every claim on day one.

APB4 digital controller for a dual-FET push/pull DC-DC converter (center-tapped transformer primary), with ASIL-D safety.

1.

Key Features

Standards & Compliance

IEC 62477-1 (power electronic systems); ISO 26262 ASIL-D SEooC (SPFM 100.00%, LFM 100.00%, PMHF 0/h, measured)

Functional Safety

ASIL-D (SEooC) · SPFM 100.00% · LFM 100.00% · PASS

ISO 26262:2018 · FMEDA available · Safety Manual included

Register Map

OffsetRegisterDescription
0x00CTRL[0]=EN [1]=OC_LATCH (OC latches a fault vs cycle-by-cycle)
0x04STATUS[0]=FAULT [1]=OC_ACTIVE [2]=PHASE (B half) [3]=SOFTSTARTING [4]=RUNNING (RO)
0x08PERIODhalf-period in clocks 0x0C DUTY on-time in clocks (<= PERIOD-DEADTIME)
0x10DEADTIMEcycles at each half start before the gate turns on
0x14SOFTSTARTclocks per soft-start duty-limit step (+1 each step until DUTY)

…4 more registers — see datasheet for the full table.

Getting Started

// Minimal instantiation
dcdc_pp #(
 .ADDR_W(6)
) u_dcdc_pp (
 .clk (clk),
 .rst_n (rst_n),
 // APB4
 .p_paddr (paddr),
 .p_psel (psel),
 .p_penable (penable),
 .p_pwrite (pwrite),
 .p_pwdata (pwdata),
 .p_prdata (prdata),
 .p_pready (pready),
 // Safety
 .err_clear (1'b0),
 .err_valid (err_valid),
 .err_code (err_code)
);

Configure via the CTRL register after reset to enable the IP and set operating parameters. Monitor err_valid / err_code for any safety faults reported by the built-in safety monitor.

Applications

Where it fits

Typically deployed in motor drives, power conversion, and sensor front-ends in automotive and industrial systems.

The case

Why license it, not build it

Skip 12–18 months
The FMEDA and the safety case are already generated. You integrate a finished safety element — you don’t stand up a safety-IP program to originate one.
One vendor, one safety story
Every block in the catalog shares the same safety architecture, fault-reaction model, and FMEDA methodology — so subsystems roll up cleanly.
Verified, not vapor
The RTL builds and passes today; the safety metrics come from analysis and fault injection against real RTL, not a datasheet promise.

Interested in Push-Pull DC-DC Converter Controller?

Pricing, the per-IP FMEDA, safety manual, and RTL data room are shared under a mutual NDA.

Talk to us →See related IP

Figures are pre-silicon engineering-grade estimates for a Safety Element out of Context (SEooC); final ASIL sign-off is the integrator’s, supported under NDA. FMEDA and Safety Manual available under NDA.

circuit-design.space · +1-971-357-1400 · anovickis@circuit-design.space