Hardware UBX/NMEA GNSS parser with checksum-verified PVT and PPS timepulse capture, ASIL-B. It is delivered as a licensable soft-IP block engineered as an ASIL-B Safety Element out of Context — not just RTL, but the complete functional-safety work package needed to carry it into an ISO 26262 program:
gnss_parser is a hardware GNSS-message parser (#DRONE-4), delivered as synthesizable SystemVerilog soft-IP with an APB4-lite control interface and built-in ISO 26262 (ASIL-B) safety instrumentation.
pps\_i rising edge into PPS_TS, with a one-shot PPS_FRESH strobefi\_\* fault-inject port for self-testgnss\_irqu-blox UBX, NMEA-0183; ISO 26262 ASIL-B SEooC, engineering-FMEDA PASS (SPFM 93.50%, LFM 90.00%, PMHF 3.18×10⁻⁹/h, pre-sign-off)
ASIL-B target (SEooC) · SPFM 93.50% · LFM 90.00% · Informational — not gated
Informational FMEDA — this IP is reported but NOT gated. The SPFM/LFM figures above are engineering estimates from a model that is not held to the ASIL metric gates (QM, safety-by-composition, a vendor-core overlay, or a pre-sign-off Technology Preview, depending on the IP). They are not a certification claim and must not be relied on as one. See the safety manual for this IP’s exact status, assumptions of use, and any open items.
ISO 26262:2018 · FMEDA available · Safety Manual included
| Offset | Register | Description |
|---|---|---|
0x00 | CTRL | [0]EN [2:1]MODE(0=auto 1=UBX 2=NMEA) [3]TMO_EN (parity-protected) |
0x04 | STATUS | [0]FIX_VALID [1]UBX_OK [2]NMEA_OK [3]STALE [4]PPS_FRESH [7:5]FIXTYPE |
0x08 | CFG | [15:0]STALE_N — fix-staleness timeout in clk-ticks (parity-protected) |
0x0C | ITOW | [31:0]iTOW (ms of GPS week) from the last UBX-NAV-PVT |
0x10 | LAT | [31:0]latitude (1e-7 deg, signed) — UBX-NAV-PVT lat |
…9 more registers — see datasheet for the full table.
// Minimal instantiation
gnss_parser #(
.ADDR_W(6)
) u_gnss_parser (
.clk (clk),
.rst_n (rst_n),
// APB4
.p_paddr (paddr),
.p_psel (psel),
.p_penable (penable),
.p_pwrite (pwrite),
.p_pwdata (pwdata),
.p_prdata (prdata),
.p_pready (pready),
// Safety
.err_clear (1'b0),
.err_valid (err_valid),
.err_code (err_code)
);Configure via the CTRL register after reset to enable the IP and set operating parameters. Monitor err_valid / err_code for any safety faults reported by the built-in safety monitor.
Typically deployed in in-vehicle networks, industrial gateways, and sensor/actuator links where a bus controller has to carry its own safety argument.
Pricing, the per-IP FMEDA, safety manual, and RTL data room are shared under a mutual NDA.
Figures are pre-silicon engineering-grade estimates for a Safety Element out of Context (SEooC); final ASIL sign-off is the integrator’s, supported under NDA. FMEDA and Safety Manual available under NDA.
circuit-design.space · +1-971-357-1400 · anovickis@circuit-design.space