SMBus-capable I²C slave — clock stretching, PEC, bus timeout, and ARA, lockstep-safe. It is delivered as a licensable soft-IP block engineered as an ASIL-B Safety Element out of Context — not just RTL, but the complete functional-safety work package needed to carry it into an ISO 26262 program:
A synthesizable SMBus-capable I2C slave soft-IP — adds SMBus clock-stretching, PEC (packet error checking, CRC-8), a clock-low bus timeout, and Alert Response Address (ARA) support on top of the same core I2C slave protocol as ip/i2c_slave.
SBS SMBus Specification v3.2; NXP I²C Specification UM10204 Rev. 7
ASIL-B (SEooC) · SPFM 92.00% · LFM 89.62% · PASS
ISO 26262:2018 · FMEDA available · Safety Manual included
| Offset | Register | Description |
|---|---|---|
0x00 | CTRL | RW [0]=EN [1]=PEC_EN [2]=STRETCH_EN [3]=ALERT_REQ (HW auto-clears once an ARA cycle returns this slave’s address) |
0x04 | ADDR | RW [6:0]=7-bit slave address |
0x08 | STATUS | RO/W1C [0]=RX_READY [1]=ADDRESSED [2]=OVERRUN(W1C) [3]=RW_DIR [4]=PEC_ERR(W1C) [5]=BUS_TIMEOUT(W1C) [6]=ALERT_ACTIVE(RO) |
0x0C | TXDATA | WO next byte to transmit on a master read (reads as 0) |
0x10 | RXDATA | RO last received byte (read clears RX_READY) |
…2 more registers — see datasheet for the full table.
// Minimal instantiation
smbus_slave #(
.ADDR_W(6)
) u_smbus_slave (
.clk (clk),
.rst_n (rst_n),
// APB4
.p_paddr (paddr),
.p_psel (psel),
.p_penable (penable),
.p_pwrite (pwrite),
.p_pwdata (pwdata),
.p_prdata (prdata),
.p_pready (pready),
// Safety
.err_clear (1'b0),
.err_valid (err_valid),
.err_code (err_code)
);Configure via the CTRL register after reset to enable the IP and set operating parameters. Monitor err_valid / err_code for any safety faults reported by the built-in safety monitor.
Typically deployed in in-vehicle networks, industrial gateways, and sensor/actuator links where a bus controller has to carry its own safety argument.
Pricing, the per-IP FMEDA, safety manual, and RTL data room are shared under a mutual NDA.
Figures are pre-silicon engineering-grade estimates for a Safety Element out of Context (SEooC); final ASIL sign-off is the integrator’s, supported under NDA. FMEDA and Safety Manual available under NDA.