The deliverable
What you’re licensing
Multi-tile INT8 systolic-GEMM integrator — TILES_M×TILES_N grid of ai_mac tiles, cluster-level ABFT + FSM DMR, ASIL-B safety. It is delivered as a licensable soft-IP block engineered as an ASIL-B Safety Element out of Context — not just RTL, but the complete functional-safety work package needed to carry it into an ISO 26262 program:
Synthesizable RTL
Portable, vendor-neutral SystemVerilog that drops onto your existing SoC fabric — no foundry or EDA-tool lock-in.
Per-IP FMEDA report
SPFM / LFM / PMHF computed against the ASIL target per ISO 26262-5 — the quantitative analysis your assessor asks for.
Safety manual
Assumptions of use, the safety mechanisms and their diagnostic coverage — written to drop straight into your safety case.
IP-XACT + integration docs
A machine-readable descriptor plus register and integration documentation for fast, low-risk bring-up.
Self-checking testbench
A self-checking testbench and a one-command build, so you can reproduce every claim on day one.
What it is
ai_mac_cluster is the multi-tile integrator for the INT8 systolic-GEMM tile (ai_mac v2): a TILES_M × TILES_N grid of SIZE × SIZE output-stationary PE tiles — default 2×2 of SIZE-4 = effective 8×8, parameterizable to e.g.
Key Features
- TILES_M×TILES_N grid of ai_mac v2 (STREAM_EN=1) SIZE×SIZE tiles — default 2×2 of SIZE-4 = effective 8×8, parameterizable to 4×4 = effective 16×16
- Output-stationary dataflow: activations broadcast along tile-rows, weights broadcast along tile-columns; M/N tiling only — K is fixed at each tile’s SIZE, no cross-tile K-reduction
- Host/DMA-fed, not bus-mapped: dedicated a_row_we/w_row_we row-write load ports and start/busy/done control, with combinational c_rd_row/col/data readback of the assembled C
- Deterministic single-clock-domain execution — no internal CDC — with fixed run latency (2·SIZE distribute beats + per-tile GEMM + SIZE collect rows) for bit-exact regression and FTTI budgeting
- Signed-INT32 accumulation per tile and at the cluster assembler, with ample headroom at the default SIZE=4 geometry (|sum| ≤ 65536 vs 2^31)
- Independent cluster-level ABFT column checksum over the assembled C (err_code 2) plus a complementary-DMR shadow on the cluster control FSM (err_code 9) — beyond each tile’s own ABFT/SECDED/DMR overlay
- One per-cluster fccu fault hub (self-sequenced APB config, err_code 1) aggregates every tile and cluster fault into a single safety_monitor err_valid/err_code[3:0] plus a critical fault_out pin; per-tile fi_* fault-injection port proves diagnostic coverage
Standards & Compliance
ISO 26262 ASIL-B SEooC; INT8 systolic-GEMM accelerator (AXI4-Stream tile interconnect, ai_mac v2 tile)
Functional Safety
ASIL-B (SEooC) · SPFM 98.63% · LFM 90.16% · PASS
ISO 26262:2018 · FMEDA available · Safety Manual included
Register Map
See datasheet for full register reference.
Getting Started
// Minimal instantiation
ai_mac_cluster #(
.ADDR_W(6)
) u_ai_mac_cluster (
.clk (clk),
.rst_n (rst_n),
// APB4
.p_paddr (paddr),
.p_psel (psel),
.p_penable (penable),
.p_pwrite (pwrite),
.p_pwdata (pwdata),
.p_prdata (prdata),
.p_pready (pready),
// Safety
.err_clear (1'b0),
.err_valid (err_valid),
.err_code (err_code)
);
Configure via the CTRL register after reset to enable the IP and set operating parameters. Monitor err_valid / err_code for any safety faults reported by the built-in safety monitor.
Applications
Where it fits
Typically deployed in safety-critical edge inference — ADAS, autonomous robotics, and machine vision.