Single-link MACsec endpoint — GCM-AES-128 AND GCM-AES-256 per SA, reuses the catalog’s own ASIL-B AES/GCM engine. It is delivered as a licensable soft-IP block engineered as an ASIL-B Safety Element out of Context — not just RTL, but the complete functional-safety work package needed to carry it into an ISO 26262 program:
A synthesizable MACsec (IEEE 802.1AE) frame authentication/encryption endpoint soft-IP, supporting both GCM-AES-128 and GCM-AES-256 independently per Security Association — a standalone digital IP sitting between a MAC and a PHY (conceptually), matching this catalog’s “digital-only, connects to an external MAC/PHY” convention already used for eth_pfc/dp_link.
SA\_CTRL.KEY256) — mixed-width links supportedaes engine’s own hardware GCM sequencer via an internal microsequencer — no AES/GHASH re-implementedIEEE 802.1AE MACsec (public shape only — clean-room reduced-scope approximation, not a verified implementation of the licensed specification)
ASIL-B (SEooC) · SPFM 97.70% · LFM 89.70% · PASS
ISO 26262:2018 · FMEDA available · Safety Manual included
| Offset | Register | Description |
|---|---|---|
0x00 | CTRL | RW [0]=RX_EN [1]=TX_EN [2]=TX_SA_SEL (select active TX SA slot 0/1) [3]=RX_DROP_ON_FAIL (0=release plaintext anyw… |
0x04 | STATUS | RO/W1C [0]=RX_BUSY (RO) [1]=TX_BUSY (RO) [2]=RX_DONE (W1C) [3]=TX_DONE (W1C) [4]=RX_AUTH_FAIL (W1C) [5]=RX_REPLAY_FAI… |
0x08 | IER | RW [7:2] = per-STATUS-bit interrupt-enable mask, aligned 1:1 to STATUS[7:2] (bits [1:0] reserved; no irq pin in v… |
0x0C | REPLAY_WINDOW | RW [15:0] = RX replay-window size (a PN more than this far behind the highest-seen PN for the matching SA is rejected… |
// Minimal instantiation
macsec_node #(
.ADDR_W(6)
) u_macsec_node (
.clk (clk),
.rst_n (rst_n),
// APB4
.p_paddr (paddr),
.p_psel (psel),
.p_penable (penable),
.p_pwrite (pwrite),
.p_pwdata (pwdata),
.p_prdata (prdata),
.p_pready (pready),
// Safety
.err_clear (1'b0),
.err_valid (err_valid),
.err_code (err_code)
);Configure via the CTRL register after reset to enable the IP and set operating parameters. Monitor err_valid / err_code for any safety faults reported by the built-in safety monitor.
Typically deployed in in-vehicle networks, industrial gateways, and sensor/actuator links where a bus controller has to carry its own safety argument.
Pricing, the per-IP FMEDA, safety manual, and RTL data room are shared under a mutual NDA.
Figures are pre-silicon engineering-grade estimates for a Safety Element out of Context (SEooC); final ASIL sign-off is the integrator’s, supported under NDA. FMEDA and Safety Manual available under NDA.
circuit-design.space · +1-971-357-1400 · anovickis@circuit-design.space