Cache-free, TCM-fed RV32IMC core for deterministic safety islands — same port list drops straight into full-ASIL-B rv32_lockstep. It is delivered as a licensable soft-IP block engineered as an ASIL-A Safety Element out of Context — not just RTL, but the complete functional-safety work package needed to carry it into an ISO 26262 program:
rv32_safe is an ASIL-B safety wrapper around the vendored OpenHW CV32E40S RV32IMC processor core (Solderpad Hardware Licence v2.1), delivered as synthesizable SystemVerilog with no instruction or data cache — a deterministic, TCM-fed core built for safety islands and a direct upgrade path to lockstep, not for raw single-thread speed.
RISC-V RV32IMC_Zicsr_Zifencei ISA; OpenHW CV32E40S (Solderpad HL v2.1); ISO 26262 ASIL-B SEooC — pre-sign-off FMEDA SPFM 51.30% / LFM 89.36% / PMHF 2.75×10⁻⁷/h (FAIL standalone; PASS via rv32_lockstep)
ASIL-A target (SEooC) · SPFM 51.30% · LFM 89.36% · Informational — not gated
Informational FMEDA — this IP is reported but NOT gated. The SPFM/LFM figures above are engineering estimates from a model that is not held to the ASIL metric gates (QM, safety-by-composition, a vendor-core overlay, or a pre-sign-off Technology Preview, depending on the IP). They are not a certification claim and must not be relied on as one. See the safety manual for this IP’s exact status, assumptions of use, and any open items.
ISO 26262:2018 · FMEDA available · Safety Manual included
See datasheet for full register reference.
// Minimal instantiation
rv32 #(
.ADDR_W(6)
) u_rv32 (
.clk (clk),
.rst_n (rst_n),
// APB4
.p_paddr (paddr),
.p_psel (psel),
.p_penable (penable),
.p_pwrite (pwrite),
.p_pwdata (pwdata),
.p_prdata (prdata),
.p_pready (pready),
// Safety
.err_clear (1'b0),
.err_valid (err_valid),
.err_code (err_code)
);Configure via the CTRL register after reset to enable the IP and set operating parameters. Monitor err_valid / err_code for any safety faults reported by the built-in safety monitor.
Typically deployed in the safety backbone of an ASIL SoC — error detection, redundancy, and the fault-reaction path that takes the system to a safe state.
Pricing, the per-IP FMEDA, safety manual, and RTL data room are shared under a mutual NDA.
Figures are pre-silicon engineering-grade estimates for a Safety Element out of Context (SEooC); final ASIL sign-off is the integrator’s, supported under NDA. FMEDA and Safety Manual available under NDA.