A dual-mode FIPS 180-4 hash accelerator — SHA-256 (default, 64 rounds) and SHA-512 (80 rounds), It is delivered as a licensable soft-IP block engineered as an ASIL-B Safety Element out of Context — not just RTL, but the complete functional-safety work package needed to carry it into an ISO 26262 program:
A dual-mode FIPS 180-4 hash accelerator — SHA-256 (default, 64 rounds) and SHA-512 (80 rounds), selected by a MODE register — delivered as synthesizable SystemVerilog soft-IP with an APB4 slave interface.
FIPS 180-4 (SHA-256/SHA-512), NIST SP 800-107 (hash security), NIST CAVS-validated test vectors. ASIL B — ISO 26262-5
ASIL-B (SEooC) · SPFM 95.00% · LFM 90.00% · PASS
ISO 26262:2018 · FMEDA available · Safety Manual included
| Offset | Register | Description |
|---|---|---|
0x00 | CTRL | [0]=INIT (W1: H <- FIPS IVs) [1]=START (W1: compress the loaded block) |
0x04 | STATUS | RO [0]=BUSY [1]=DONE |
0x08..0x44 | MSG0..MSG15 | (16×32-bit, SHA-256 block OR SHA-512 block words 0..15) |
0x48..0x64 | DIGEST0..DIGEST7 | (RO H[0..7] low 32 bits, valid for both modes) |
0x68 | IER | [0]=DONE_IE 0x6C ISR RW1C [0]=DONE |
…2 more registers — see datasheet for the full table.
// Minimal instantiation
sha256 #(
.ADDR_W(6)
) u_sha256 (
.clk (clk),
.rst_n (rst_n),
// APB4
.p_paddr (paddr),
.p_psel (psel),
.p_penable (penable),
.p_pwrite (pwrite),
.p_pwdata (pwdata),
.p_prdata (prdata),
.p_pready (pready),
// Safety
.err_clear (1'b0),
.err_valid (err_valid),
.err_code (err_code)
);Configure via the CTRL register after reset to enable the IP and set operating parameters. Monitor err_valid / err_code for any safety faults reported by the built-in safety monitor.
Typically deployed in secure boot, firmware authentication, key storage, and confidential on-board communication.
Pricing, the per-IP FMEDA, safety manual, and RTL data room are shared under a mutual NDA.
Figures are pre-silicon engineering-grade estimates for a Safety Element out of Context (SEooC); final ASIL sign-off is the integrator’s, supported under NDA. FMEDA and Safety Manual available under NDA.
circuit-design.space · +1-971-357-1400 · sales@circuit-design.space