Board FIT Calculator — Failure Rate and MTBF from a BOM

Enter what is on the board and the temperature it runs at. The calculator returns a board-level failure rate and MTBF, scales it to your ambient, and ranks which component classes are actually spending it.

Component classQtyFIT each (at reference)ContributionShare
Board failure rate
FIT at ambient
MTBF
Temperature factor
Arrhenius, vs reference
Parts
total placements

Runs entirely in your browser. Nothing is uploaded, stored, or sent anywhere.

Read this before trusting a number. The FIT values loaded above are illustrative orders of magnitude, not data. Real base failure rates come from IEC 62380, SN 29500, FIDES or your suppliers' own reliability reports, and they differ from each other — sometimes by more than a factor of two for the same part class. Every rate in the table is editable, and you should replace all of them with figures from a source you can name in a report. What this tool contributes is the arithmetic, the temperature scaling and the ranking, not the inputs.

What a board FIT number is for

A failure rate on its own settles very little. Its value is that it is the input to two other questions. The first is commercial: what warranty return rate does this design imply, and can the business live with it. The second is safety: a hardware safety analysis begins with a failure rate per element, and if you cannot produce one, the analysis cannot start.

That second use is why this calculator sits next to the safety tools rather than on its own. A board FIT total is the raw λ that the FMEDA rollup consumes. Split across elements, with a safe-fault fraction and a diagnostic coverage argued for each, it becomes SPFM, LFM and PMHF — and only then does it say anything about an ASIL.

Temperature is usually the biggest lever

Failure rates are quoted at a reference temperature, and they do not stay there. The standard correction is the Arrhenius relation:

AF = exp( Ea/k × (1/Tref − 1/Tuse) )  ·  k = 8.617×10−5 eV/K, temperatures in kelvin

With an activation energy of 0.7 eV, moving from 40 °C to 85 °C multiplies the rate by roughly twenty-six — the example board above goes from about 180 years of continuous operation to about 7. That single number swamps almost any component-selection argument, which is why a mission profile that has not been agreed is the most common reason two analyses of the same board disagree. Change the ambient field above and watch the total move; then consider that the ambient inside an enclosure is not the ambient on the datasheet.

Activation energy is not universal — 0.7 eV is a common default for silicon, but electrolytics, solder joints and connectors age by different mechanisms with different energies, and a rigorous analysis applies them per class rather than globally. This tool applies one value to everything, which is a real simplification.

Where the rate actually comes from

Look at the share column rather than the total. On most boards a handful of classes supply the majority of the failure rate, and they are rarely the parts anyone worried about during design. Electrolytic capacitors and connector pins routinely outweigh the microcontroller, because reliability follows count and stress, not complexity or cost. If you want a lower number, the ranking tells you the only three lines worth touching.

What this leaves out

Where this fits

PCB design and FMEDA/FMEA review are both primary service lines here, and this calculator sits exactly where they meet. If you need a board failure rate you can defend — sourced, derated, with a stated mission profile and a written rationale — that is an FMEDA gap review or a from-scratch build, one to two weeks and three to eight weeks respectively. Both end in a report you keep.

More free tools

Each of these runs entirely in your browser. Nothing is uploaded, stored or sent anywhere, and none of them needs an email address.

ASIL determination →
Severity, exposure and controllability to an ASIL, with the reasoning shown.
FIT & PMHF budget →
Failure rate and diagnostic coverage to SPFM, LFM and PMHF for one element.
FMEDA rollup →
Many elements rolled up to system SPFM, LFM and PMHF, ranked by contribution.
Solder joint fatigue →
Coffin-Manson thermal cycling life, scaled from a qualification test.

See all 49 engineering tools →

Stay in touch

New tools and notes, once a month at most

We add tools here fairly often and write up the things worth writing up — a stackup that behaved oddly, a standard that turned out to be obsolete, a calculator that was quietly wrong. Join and you get told when something new lands.

One email a month at the very most, and usually less. No drip sequence, no sales cadence, no sharing your address with anyone. Unsubscribe whenever you like.

Join the list →

Talk to us about a review →